Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (78)
- (185)
- (51)
- (126)
- (1)
- (1)
- (45)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (45)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (1)
- (36)
- (1)
- (1)
- (809)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (2)
- (3)
- (133)
- (632)
- (59)
Filtered Search Results
Cytiva Whatman™ 0.45 μm Pore Size (ME 25) Mixed Cellulose Ester Membranes, White/Black Grid
Whatman™ (ME 25) Mixed Cellulose Ester Membranes, White/Black Grid are particularly effective in applications requiring higher flow rates and larger volume filtration. Supplied with clearly defined grid lines at regularly spaced intervals to assist in microbiological colony counting.
Sartorius Hydrophobic Edged Nonsterile Cellulose Nitrate and Acetate Membrane Filters
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Color | White |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophobic |
| Sterility | Non-sterile |
Sartorius Cellulose Nitrate Membrane Filter
Cellulose nitrate membrane filters with 142 mm diameters are hydrophilic, have high flow rates thanks to their symmetrical structure and are compatible with aqueous solutions, hydrocarbons and several other organic solvents.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 142 mm |
| Quantity | 100/Cs. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Cytiva Whatman™ Polyamide Membranes
Universal filter made from pure polyamide for clarification and sterile filtration
| Thickness (Metric) | 110 μm |
|---|---|
| Material | Polyamide |
| Hydrophobicity | Hydrophilic |
Sartorius Cellulose Acetate Membrane Filter
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cellulose acetate membrane filters with 142 mm diameter combine thermal stability with exceptionally low adsorption characteristics.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Diameter (Metric) | 142 mm |
| Quantity | 100/Cs. |
| Material | Cellulose Acetate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Sartorius Microsart™ @Filter 100 in Bags
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Sample Volume | 100 ml |
| Material | Cellulose Nitrate |
| Sterility | Sterile |
MilliporeSigma™ Omnipore™ Membrane Filters, 0.45 μm
Hydrophilic PTFE polymer membrane filter compatible with virtually all solvents, acids, and alkaline solutions. Omnipore™ Membrane Filters are biologically and chemically inert.
MilliporeSigma™ MF-Millipore™ Membrane Filter, 1.2 μm, Gridded
Mixed cellulose esters (MCE) membrane, hydrophilic
GVS Magna™ Nylon Membrane Filters
Plain white nylon membranes offer low extractables, high uniformity
| Material | Nylon |
|---|---|
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Permit use for aqueous filtration without wetting and organic solvent filtrations such as HPLC |
| Autoclavable | Autoclavable |
| Thickness (Metric) | 130 μm |
|---|---|
| Color | White |
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Laminated membranes are ideal for vent filtration, phase separation, aerosol sampling. |
| Autoclavable | Autoclavable |
GVS Nitrocellulose-Mixed Esters of Cellulose Membrane Filters
Uniform microporous structure has low extractables, low ash
| Material | MCE |
|---|---|
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Microbiological determinations; industrial hygiene procedures; clarifying aqueous solutions; determination of lead, chromium, cadmium, beryllium, arsenic, airborne asbestos and other particulates. |
GVS Poretics™ 25 mm Polycarbonate Disc
Made from a thin, microporous polycarbonate film material. It is ideally suited for use in blood assays and high-purity and general filtration. Though polycarbonate is hydrophobic, the membrane is treated with a wetting agent to make it hydrophilic.
| Disposable | Limited-use |
|---|---|
| Type | Disc Membrane |
| Format | Disc |
| Material | PCTE |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
GVS Magna™ 47 mm Nylon Disc
A supported, naturally hydrophilic membrane designed to wet out evenly and retain its superior strength during use in general filtration or medical assays.
| Disposable | Limited-use |
|---|---|
| Type | Disc Membrane |
| Format | Disc |
| Material | Nylon |
| Filter Type | Membrane Filter |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
GVS Quartz Microfiber Filter, Disc
GVS Quartz Microfiber Filters are D0QF1 Standard grade and binder-free with a GSM of 85 g/m2.
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Material | Quartz Fiber |
| Filter Type | Microporous Filter |
| Sterility | Non-sterile |
GVS PCTE Filter Membranes: Plain Hydrophilic
Smooth, flat surface for even distribution in a single plane.
| Material | PCTE |
|---|